Is optoelectronic plethysmography a valid instrument to measure inspiratory capacity?

Authors

  • Danielle Soares Rocha Vieira Universidade Federal de Santa Catarina; Department of Physical Therapy
  • Daniele Aparecida Gomes Pereira Universidade Federal de Minas Gerais; Department of Physical Therapy
  • Mariana Hoffman Barbosa Universidade Federal de Minas Gerais; Rehabilitation Science Program
  • Verônica Franco Parreira Universidade Federal de Minas Gerais; Department of Physical Therapy

DOI:

https://doi.org/10.590/1809-2950/13875622022015

Abstract

The aim of this study was to evaluate the concurrent validity of the optoelectronic plethysmography (OEP) to measure inspiratory capacity (IC) at rest and during submaximal exercise in healthy subjects. Twelve subjects (6 Male/6 Female; 23.8±1.34 yrs) with normal body mass index and lung function completed the study protocol. Participants were assessed at rest and during a 12-minute submaximal exercise protocol on a cycle ergometer. IC maneuvers were simultaneously recorded by OEP system and by a spirometer at rest and during exercise. The percentage of discrepancy between measurements, linear regression analysis and Bland-Altman method were used for data analysis. The study was approved by the institution ethics committee. It was considered 150 valid IC maneuvers for analysis (44 for resting and 106 for exercise). The percentage of discrepancy between the measurements were -9.6 (8.6%) at rest and -4.6 (5.5%) during exercise. Regression analysis showed good linear associations between methods at rest (r2=0.90; p=0.0002) and during exercise (r2=0.96; p=0.0008). Bland-Altman analysis using data obtained during exercise showed a bias between the two methods of 0.13L. The limits of agreement indicate that the difference between methods can vary from -0.04L to 0.57L. Additionally, data was equally distributed between the upper and lower limits, demonstrating no systematic overestimation or underestimation of the IC by any of the instruments. In conclusion, this study demonstrated that the OEP is a valid evaluation system to measure IC of healthy individuals at rest and during submaximal exercise.

Downloads

Download data is not yet available.

References

Gadotti IC, Vieira ER, Magee DJ. Importance and clarification

of measurement properties in rehabilitation. Rev Bras

Fisioter. 2006;10(2):137-46.

Aliverti A. Opto-electronic plethysmography: new findings

in chronic obstructive pulmonary disease. Int J Respir Care.

;(2):45-50.

Aliverti A, Pedotti A. Opto-electronic plethysmography.

Monaldi Arch Chest Dis. 2003;59(1):12-6.

Iandelli I, Aliverti A, Kayser B, Dellaca R, Cala SJ, Duranti R, et

al. Determinants of exercise performance in normal men with

externally imposed expiratory flow limitation. J Appl Physiol.

;92(5):1943-52.

Parreira VF, Vieira DS, Myrrha MA, Pessoa IM, Lage SM,

Britto RR. Optoelectronic plethysmography: a review of the

literature. Rev Bras Fisioter. 2012;16(6):439-53.

Aliverti A, Dellaca R, Pelosi P, Chiumello D, Pedotti A, Gattinoni

L. Optoelectronic plethysmography in intensive care patients.

Am J Respir Crit Care Med. 2000;161(5):1546-52.

Aliverti A, Dellaca R, Pelosi P, Chiumello D, Gatihnoni L,

Pedoti A. Compartmental analysis of breathing in the supine

and prone positions by optoelectronic plethysmography.

Ann Biomed Eng. 2001;29(1):60-70.

Cala SJ, Kenyon CM, Ferrigno G, Carnevali P, Aliverti A,

Pedotti A, et al. Chest wall and lung volume estimation

by optical reflectance motion analysis. J Appl Physiol.

;81(6):2680-9.

Vogiatzis I, Georgiadou O, Golemati S, Aliverti A, Kosmas

E, Kastanakis E, et al. Patterns of dynamic hyperinflation

during exercise and recovery in patients with severe chronic

obstructive pulmonary disease. Thorax. 2005;60(9):723-9.

Aliverti A, Stevenson N, Dellaca RL, Lo Mauro A, Pedotti

A, Calverley PM. Regional chest wall volumes during

exercise in chronic obstructive pulmonary disease. Thorax.

;59(3):210-6.

Vieira DS, Hoffman M, Pereira DA, Britto RR, Parreira VF.

Optoelectronic plethysmography: intra-rater and interrater reliability in healthy subjects. Respir Physiol Neurobiol.

;189(3):473-6.

Dellaca RL, Ventura ML, Zannin E, Natile M, Pedotti A,

Tagliabue P. Measurement of total and compartmental

lung volume changes in newborns by optoelectronic

plethysmography. Pediatr Res. 2010;67(1):11-6.

Kenyon CM, Cala SJ, Yan S, Aliverti A, Scano G, Duranti R, et

al. Rib cage mechanics during quiet breathing and exercise in

humans. J Appl Physiol. 1997;83(4):1242-55.

Duranti R, Filippelli M, Bianchi R, Romagnoli I, Pellegrino

R, Brusasco V, et al. Inspiratory capacity and decrease

in lung hyperinflation with albuterol in COPD. Chest.

;122(6):2009-14.

World Health Organization. Global database on body mass

index: an interactive surveillance tool for monitoring nutrition

transition [Internet]. Geneva: WHO. 2004 [access in: oct. 20

. Available at: http://apps.who.int/bmi.

Pereira CA, Sato T, Rodrigues SC. New reference values for

forced spirometry in white adults in Brazil. J Bras Pneumol.

;33(4):397-406.

Neder JA, Nery LE, Castelo A, Andreoni S, Lerario MC,

Sachs A, et al. Prediction of metabolic and cardiopulmonary

responses to maximum cycle ergometry: a randomised

study. Eur Respir J. 1999;14(6):1304-13.

O’Donnell DE, Webb KA. Exertional breathlessness in

patients with chronic airflow limitation. The role of lung

hyperinflation. Am Rev Respir Dis. 1993;148(5):1351-7.

Dolmage TE, Goldstein RS. Repeatability of inspiratory

capacity during incremental exercise in patients with severe

COPD. Chest. 2002;121(3):708-14.

American Thoracic S, American College of Chest P. ATS/

ACCP Statement on cardiopulmonary exercise testing. Am J

Respir Crit Care Med. 2003;167(2):211-77.

Neder JA, Fuld JP, Overend T, Thirlwell J, Carter R, Stevenson

R, et al. Effects of formoterol on exercise tolerance

in severely disabled patients with COPD. Respir Med.

;101(10):2056-64.

Portney G, Watkins, P.M. Regression. In: Hall PP, editors

Foundations of Clinical Research Applications to Practice. 3a

ed. New Jersey: Pearson Prentice Hall; 2008. p. 539-67.

Bland JM, Altman DG. Statistical methods for assessing

agreement between two methods of clinical measurement.

Lancet. 1986;1(8476):307-10.

Bland JM, Altman DG. Measuring agreement in method

comparison studies. Stat Methods Med Res. 1999;8(2):135-60.

Aliverti A, Dellaca R, Pedotti A. Optoelectronic

plethysmography: a new tool in respiratory medicine. Recent

Prog Med. 2001;92(11):644-7.

Downloads

Published

2015-06-06

Issue

Section

Original Researches

How to Cite

Is optoelectronic plethysmography a valid instrument to measure inspiratory capacity?. (2015). Fisioterapia E Pesquisa, 22(2), 155-160. https://doi.org/10.590/1809-2950/13875622022015