Reproducibility and agreement between different protocols of dynamic baropodometry during gait: a preliminary study

Authors

DOI:

https://doi.org/10.1590/1809-2950/17018227042020

Keywords:

Foot, Data Accuracy, Gait Analysis

Abstract

The identification of plantar pressure during gait is used by clinicians and researchers to verify burden on the plantar structure. In this study, different protocols have been employed for this purpose. The aim of this study was to verify the reproducibility and agreement of shortened gait protocols to identify dynamic plantar pressure in asymptomatic young people. Fifteen volunteers were submitted to the shortened one-step and three-step protocols and to the standard midgait protocol in three moments: initial, after one day and after seven days. For each of the eight foot masks, the measurements of peak plantar pressure and pressure-time integral were considered. Reproducibility was analyzed by one-way Anova test and intraclass correlation coefficient, while the agreement between the protocols was verified through paired t-test, Pearson’s moment-product correlation and Bland-Altman plot. The results showed that the three-step protocol presented higher reproducibility in both measurements of dynamic plantar pressure. Regarding the agreement between protocols, although the shortened ones showed a tendency to underestimate the standard midgait measurements, most foot masks showed no statistical differences between mean scores. Furthermore, through the Bland-Altman technique, there was substantial agreement capacity between the one-step, three-step and midgait protocols measurements. In conclusion, the shortened protocols should be selected according to the measurement of interest of plantar pressure and foot masks to be analyzed. The evidence of reproducibility and agreement was more favorable for the use of the three-step protocol.

Downloads

Download data is not yet available.

References

Miura N, Nagai K, Tagomori K, Ikutomo H, Okamura K, Okuno

T, et al. Plantar pressure distribution during standing in women

with end-stage hip osteoarthritis. Gait Posture. 2020;76:39-43.

doi: 10.1016/j.gaitpost.2019.10.026

Wei Z, Zhang Z, Jiang J, Zhang Y, Wang L. Comparison of plantar

loads among runners with different strike patterns. J Sports

Sci. 2019;37(18):2152-8. doi: 10.1080/02640414. 2019.1623990

Hähni M, Hirschmüller A, Baur H. The effect of foot orthoses

with forefoot cushioning or metatarsal pad on forefoot peak

plantar pressure in running. J Foot Ankle Res. 2016;9:44. doi:

1186/s13047-016-0176-z

Chatwin KE, Abbott CA, Boulton AJM, Bowling FL, Reeves ND. The

role of foot pressure measurement in the prediction and prevention

of diabetic foot ulceration – A comprehensive review. Diabetes

Metab Res Rev. 2020;36(4):e3258. doi: 10.1002/dmrr.3258

Hazari A, Maiya A, Agouris I, Monteiro A, Shivashankara.

Prediction of peak plantar pressure for diabetic foot: The

regressional model. Foot (Edinb). 2019;40:87-91. doi: 10.1016/j.

foot.2019.06.001

Ma CZ, Zheng YP, Lee WC. Changes in gait and plantar foot

loading upon using vibrotactile wearable biofeedback system

in patients with stroke. Top Stroke Rehabil. 2018;25(1):20-7. doi:

1080/10749357.2017.1380339

Zulkifli SS, Loh WP. A state-of-the-art review of foot pressure.

Foot Ankle Surg. 2020; 26(1):25-32. doi: 10.1016/j.fas.2018.12.005

Arts ML, Bus SA. Twelve steps per foot are recommended for

valid and reliable in-shoe plantar pressure data in neuropathic

diabetic patients wearing custom made footwear. Clin

Biomech (Bristol, Avon). 2011;26(8):880-4. doi: 10.1016/j.

clinbiomech.2011.05.001

Fascione JM, Crews RT, Wrobel JS. Association of footprint

measurements with plantar kinetics: A linear regression

model. J Am Podiatr Med Assoc. 2014;104(2):125-33. doi:

7547/0003-0538-104.2.125

Wearing SC, Urry S, Smeathers JE, Battistutta D. A comparison

of gait initiation and termination methods for obtaining plantar

foot pressures. Gait Posture. 1999;10(3):255-63. doi: 10.1016/

s0966-6362(99)00039-9

Bryant A, Singer K, Tinley P. Comparison of the reliability of

plantar pressure measurements using the two-step and midgait

methods of data collection. Foot Ankle Int. 1999;20(10):646-50.

doi: 10.1177/107110079902001006

Bus SA, de Lange A. A comparison of the 1-step, 2-step, and

-step protocols for obtaining barefoot plantar pressure data

in the diabetic neuropathic foot. Clin Biomech (Bristol, Avon).

;20(9):892-9. doi: 10.1016/j.clinbiomech.2005.05.004

Izquierdo-Renau M, Pérez-Soriano P, Ribas-García V, Queralt

A. Intra and intersession repeatability and reliability of the

S-Plate® pressure platform. Gait Posture. 2017;52:224-6. doi:

1016/j.gaitpost.2016.12.001

Godi M, Turcato AM, Schieppati M, Nardone A. Test-retest

reliability of an insole plantar pressure system to assess gait

along linear and curved trajectories. J Neuroeng Rehabil.

;11:95. doi: 10.1186/1743-0003-11-95

Patrick K, Donovan L. Test-retest reliability of the Tekscan®

F-Scan® 7 in-shoe plantar pressure system during treadmill

walking in healthy recreationally active individuals. Sports

Biomech. 2018;17(1):83-97. doi: 10.1080/14763141.2017.1355010

Menz HB. Analysis of paired data in physical therapy research:

time to stop double-dipping? J Orthop Sports Phys Ther.

;35(8):477-8. doi: 10.2519/jospt.2005.0108

Nouman M, Dissaneewate T, Leelasamran W, Chatpun S. The

insole materials influence the plantar pressure distributions in

diabetic foot with neuropathy during different walking activities.

Gait Posture. 2019;74:154-61. doi: 10.1016/j.gaitpost.2019.08.023

Borg J, Mizzi S, Formosa C. Peak pressure data and pressuretime integral in the contralateral limb in patients with diabetes

and a trans-tibial prosthesis. Gait Posture. 2018;64:55-8.

doi: 10.1016/j.gaitpost.2018.05.023

Van der Leeden M, Dekker JH, Siemonsma PC, Lek-Westerhof

SS, Steultjens MPM. Reproducibility of plantar pressure

measurements in patients with chronic arthritis: a comparison

of one-step, two-step, and three-step protocols and an

estimate of the number of measurements required. Foot Ankle

Int. 2004;25(10):739-44. doi: 10.1177/107110070402501008

Peters EJG, Urukalo A, Fleishli JG, Lavery LA. Reproducibility

of gait analysis variables: one-step versus three-step method

of data acquisition. J Foot Ankle Surg. 2002;41(4):206-12.

doi: 10.1016/s1067-2516(02)80016-3

Harrison AJ, Folland JP. Investigation of gait protocols for

plantar pressure measurement of non-pathological subjects

using a dynamic pedobarograph. Gait Posture. 1997;6(1):50-5.

doi: 10.1016/S0966-6362(96)01095-8

McClymont J, Pataky TC, Crompton RH, Savage R, Bates KT.

The nature of functional variability in plantar pressure during a

range of controlled walking speeds. R Soc Open Sci. 2016;3(8):

-14. doi: 10.1098/rsos.160369

Fan Y, Li Z, Han S, Lv C, Zhang B. The influence of gait speed

on the stability of walking among the elderly. Gait Posture.

;47:31-6. doi: 10.1016/j.gaitpost.2016.02.018

Xu C, Wen XX, Huang LY, Shang L, Cheng XX, Yan YB, Lei

W. Normal foot loading parameters and repeatability of the

Footscan® platform system. J Foot Ankle Res. 2017;10:30.

doi: 10.1186/s13047-017-0209-2

Telfer S, Bigham JJ. The influence of population characteristics

and measurement system on barefoot plantar pressures: A

systematic review and meta-regression analysis. Gait Posture.

;67:269-76. doi: 10.1016/j.gaitpost.2018.10.030

Deschamps K, Birch I, McInnes J, Desloovere K, Matricali

GA. Inter- and intra-observer reliability of masking in

plantar pressure analysis. Gait Posture. 2009;30(3):379-82.

doi: 10.1016/j.gaitpost.2009.06.015

Wallace J, White H, Augsburger S, Walker J. Development of a

method to produce a valid and reliable foot mask for plantar

pressure evaluation in children with clubfoot. J Pediatr Orthop

B. 2020 [Preprint]. doi: 10.1097/BPB.0000000000000801

Giacomozzi C, Stebbins JA. Anatomical masking of pressure

footprints based on the Oxford Foot Model: validation and

clinical relevance. Gait Posture. 2017;53:131-8. doi: 10.1016/j.

gaitpost.2016.12.022

Published

2020-09-05

Issue

Section

Original Research

How to Cite

Reproducibility and agreement between different protocols of dynamic baropodometry during gait: a preliminary study. (2020). Fisioterapia E Pesquisa, 27(4), 337-346. https://doi.org/10.1590/1809-2950/17018227042020