Accuracy and Internal Fit of 3D printed Occlusal Splint, according to the printing position

A technique report

Authors

  • Mayra Torres Vasques Department of Prosthodontics, School of Dentistry, University of São Paulo
  • Dalva Cruz Laganá Department of Prosthodontics, School of Dentistry, University of São Paulo

DOI:

https://doi.org/10.11606/issn.2357-8041.clrd.2018.148012

Abstract

Understanding the importance of 3D printing strategies is a key to obtain predictable, optimized and consistent dental appliances using digital technologies. This study aims to present the influence of printing orientation on the intraoral fit of full arch coverage splints. Splints were designed for two patients using the CAD software and printed in a SLA 3D printer with different orientations (0, 30, and 90 degrees), and the internal fit was checked on patients’ mouth. Differen­ces between the fit of the splints were verified, with the worst results for 90º oriented splints, although more detailed studies are recommended by the authors.

DESCRIPTORS | Three-Dimensional Printing; Accuracy; Dimensional Measurement; Occlusal Splint; Print Orientation.

Downloads

Download data is not yet available.

Downloads

Published

2018-10-04

Issue

Section

Case report or technical report

How to Cite

Vasques, M. T., & Laganá, D. C. (2018). Accuracy and Internal Fit of 3D printed Occlusal Splint, according to the printing position: A technique report. Clinical and Laboratorial Research in Dentistry. https://doi.org/10.11606/issn.2357-8041.clrd.2018.148012