Amlodipine^i1^sdeterminat, Spectrofluorimetric method^i1^svalidat, Human plasmaAbstract
A rapid and sensitive spectrofluorimetric method was developed for the determination of amlodipine (AD), a calcium channel blocker, in the plasma. The type of solvent, the wavelength range, and the range of AD concentration were selected to optimize the experimental conditions. The calibration curves were linear (r² >;0.997) in the concentration range of 0.1-12.5 ppm of AD. The limit of quantitation and limit of detection values for the method for plasma samples were 0.1 ppm and 0.07 ppm, respectively. The precision calculated as the relative standard deviation was less than 3.5%, and the accuracy (relative error) was better than 5.5% (n=6). The method developed in this study can be directly and easily applied for the determination of AD in the plasma without derivatization in plasma.Downloads
Download data is not yet available.
Downloads
Published
2012-12-01
Issue
Section
Articles
License
All content of the journal, except where identified, is licensed under a Creative Commons attribution-type BY.
The on-line journal has open and free access.
How to Cite
Spectrofluorimetric determination of amlodipine in human plasma without derivatization . (2012). Brazilian Journal of Pharmaceutical Sciences, 48(4), 719-725. https://doi.org/10.1590/S1984-82502012000400016