Evaluation of operational parameters for clinical evaluation of skin hydration by corneometry method

Authors

DOI:

https://doi.org/10.1590/

Keywords:

Skin hydration, Non-invasive methods, Cosmetics, Corneometer

Abstract

The Corneometer CM® 825 from Courage & Khazaka electronic GmbH is widely utilized in clinical efficacy testing of cosmetics. Assessing methodological variables is crucial for ensuring the reliability of the process. The aim of this study was to evaluate the operational and instrumental parameters of the Corneometer CM® 825 in the clinical assessment of skin hydration levels. Precision and accuracy of the measurements were assessed by measuring hydration levels on 10 participants in specific areas of the forearm and face. Three different skin conditions (dry, normal, and hydrated) resulting from the use or non-use of moisturizing cosmetics and a drying promoter were evaluated within 120 minutes of their application. The electrical capacitance method demonstrated good repeatability, with coefficients of variation mostly below 10%. However, higher variability was observed in inter-observer readings. The equipment exhibited high sensitivity and accurately discriminated the differences between hydrated and dry skin. Operational training and standardization of the methodology are essential to ensure accurate, reproducible, and reliable results in studies utilizing the Corneometer equipment for assessing skin hydration levels.

Downloads

References

Amarante O, Caldas E, Brito N, Santos T, Vele M. Validação de métodos analíticos: uma breve revisão. Cad Pesq. 2001; 12: 116-131.

Anthonissen M, Daly D, Peeters R, Van Brussel M, Fieuws S, Moortgat P, et al. Reliability of Repeated Measurements on Post-Burn Scars with Corneometer CM 825®. Skin Res Technol. 2015; 21: 302-12.

ANVISA - Agência Nacional De Vigilância Sanitária (Brasil). Resolução nº 166, de 24 de julho de 2017. Dispõe sobre a validação de métodos analíticos e dá outras providências. Diário Oficial da União, 25 jun 2017.

Barel A, Clarys P. Skin Capacitance. In: Berardesca E, Maibach H, Wilhelm K, editors. Non Invasive Diagnostic Techniques In Clinical Dermatology. 1st ed. Springer Berlin, Heidelberg. 2013. p. 357-366.

Berardesca E. EEMCO guidance for the assessment of stratum corneum hydration: electrical methods. Skin Res Technol. 1997; 3: 126-32.

Chaudhuri R, bojanowski K. Improvement of hydration and epidermal barrier function in human skin by a novel compound isosorbide dicaprylate. Int J Cosmet Sci. 2017; 39: 518-526.

Clarys P, Clijsen R, Taeymans J, Barel AO. Hydration measurements of the stratum corneum: comparison between the capacitance method (digital version of the Corneometer CM 825®) and the impedance method (Skicon-200EX®). Skin Res Technol. 2011; 18: 316-23.

Clarys P, Clijsen R, Barel AO. Influence of probe application pressure on in vitro and in vivo capacitance (Corneometer CM 825®) and conductance (Skicon 200 EX®) measurements. Skin Res Technol. 2011; 17: 445-50.

Courage & Khazaka Eletronic Gmbh. Manual Corneometer® CM 825. Germany, 2019. Available from: https://www.courage-khazaka.de/en/downloads-en/item/prospekt-cm825-e

» https://www.courage-khazaka.de/en/downloads-en/item/prospekt-cm825-e

Crowther J. Understanding effects of topical ingredients on electrical measurement of skin hydration. Int J Cosmet Sci. 2016; 38: 589-598.

Darbre PD. Aluminium, antiperspirants and breast cancer. J inorg biochem. 2005; 99: 1912-9.

Draelos ZD. The science behind skin care: Moisturizers. J Cosmetic Dermatol. 2018; 17: 138-44.

Fitzpatrick TB, Pathar M, Parrish J. Protection of human skin against the effects of the sunburn ultraviolet (290-320 nm). In: Fitzpatrick, TB, editor. Sunlight and man, normal and abnormal photobiological responses. Tokyo: Etials, 1974. p. 751-765.

Gonçalves GMS, Campos PMBGM. Aplicação de métodos de biofísica no estudo da eficácia de produtos dermocosméticos. Braz J Pharm Sci. 2009; 45: 1-10.

Heinrich U, Koop U, Leneveu-Duchemin M-C, Osterrieder K, Bielfeldt S, Chkarnat C, et al. Multicentre comparison of skin hydration in terms of physical-, physiological- and product-dependent parameters by the capacitive method (Corneometer CM 825). Int J Cosmet Sci. 2003; 25: 45-53.

Kirtschig G, Schaefer C. Dermatological medications and local therapeutics. Drugs During Pregnancy and Lactation. 2015: 467-92.

Korać R, Krajišnik D, Milić J. Sensory and instrumental characterization of fast inverting oil-in-water emulsions for cosmetic application. Int J Cosmet Sci. 2015; 38: 246-56

Lodén M, Hagforsen E, Lindberg M. The presence of body hair influences the measurement of skin hydration with the Corneometer. Acta Derm Venereol. 1995; 75(6): 449-50.

Marrakchi S, Maibach HI. Biophysical parameters of skin: map of human face, regional, and age-related differences. Contact Derm. 2007; 57(1): 28-34.

Møss J. The effect of 3 moisturisers on skin surface hydration: Electrical conductance (Skicon-200), capacitance (Corneometer CM420), and transepidermal water loss (TEWL). Skin Res Technol. 1996; 2(1): 32-36.

Nolan K, Marmur E. Moisturizers: reality and the skin benefits. Dermatol Ther. 2012; 25(3): 229-33.

Phillips SD, Estler WT, Doiron T, Eberhardt KR, Levenson MS. A Careful Consideration of the Calibration Concept. J Res Natl Inst Stand Technol. 2001; 106(2): 371-9.

Piérard GE, Elsner P, Marks R, Masson P, Paye M, EEMCO Group. EEMCO guidance for the efficacy assessment of antiperspirants and deodorants. Skin Pharmacol Appl Skin Physiol. 2003; 16(5): 324-42.

Proksch E, Brandner JM, Jensen JM. The skin: an indispensable barrier. Exp Dermatol. 2008; 17(12): 1063-72.

Pum J. A practical guide to validation and verification of analytical methods in the clinical laboratory. Adv Clin Chem. 2019; 90: 215-281.

Ravichandran V, Shalini S, Sundram K, Harish R. Validation of analitical methods -strategies and importance. Int J Pharm Pharm. 2010; 2(3): 18-22.

Rogiers V, Balls M, Basketter D, Berardesca E, Edwards C, Elsner P, et al. The potential use of non-invasive methods in the safety assessment of cosmetic products. Altern Lab Anim. 1999; 27(4): 515-37.

Wilhelm K-P. Possible Pitfalls in Hydration Measurements. Curr Probl Dermatol. 1998; 223-34.

Downloads

Published

2025-02-11

Issue

Section

Article

How to Cite

Evaluation of operational parameters for clinical evaluation of skin hydration by corneometry method. (2025). Brazilian Journal of Pharmaceutical Sciences, 61. https://doi.org/10.1590/